Search

KL-95 Series Pressure Transducers with display

Industries: Semiconductor , Industrial
Call for pricing
“Flow Through” Pressure Transducer w/ Onboard Display The KL95 is a “flow through” pressure transducer suitable for use in monitoring pressure of various high-purity and corrosive/aggressive fluids. The “flow through” design provides for minimal “dead volume” which reduces the potential for contamination of the measured fluid/process. The KL95 is provided with an integrally mounted local LED display and is available in two standard pressure ranges.

The KL95 is a “flow through” pressure transducer suitable for use in monitoring pressure of various high-purity and corrosive / aggressive fluids. The “flow through” design provides for minimal “dead volume” which reduces the potential for contamination of the measured fluid / process. The KL95 is provided with an integrally mounted local LED display and is available in two standard pressure ranges.

Features:

• 1% full-scale accuracy
• Local LED Display
• Capable of measuring gauge pressure
• All PFA wetted part construction
• No o-ring seals or fluids fill
• Choice of end fittings: tube, flare, or Pillar

Material of Wetted Parts

PFA / PTFE

Material of Case

Body

PFA / PTFE

 

Display Case

Polypropylen, PET

Pressure Range (Max Display Value)

0 to 50 psi (50.0), 0 to 75 psi (75.0)

Allowable Maximum Pressure

105 psi

Display (LED 4 Digits)

Accuracy

±1% F.S. ±1 digit

 

Rate

0.2 seconds

Temperature Coefficient

 +/- 0.05 % F.S. / deg. C

Power and Supply Current

24VDC ±10% (30mA DC max.)

Comparator Output

Open Collector

2 outputs of type NPN (30VDC, 10mA max)

 

Response Time

Within 5ms

Analog Output

Voltage Output

0 to 10VDC

Current Output

4 to 20mA

Output Accuracy

+/- 1 % F.S.

Response Time

Within 50 ms

Connection Type

Flaretek, Super Pillar 300, Tube Ends

Connection Sizes

1/4” , 3/8” , 1/2” , 3/4”

Operating Temperature Range

10 to 60°C

Operating Humidity Range

35 to 85 % RH ( non-condensing )

Protection

IP-54 (an atmosphere release hole exists)

Cable Length

4 m

Weight

280 g

 

For additional specification details, please refer to the product data sheet located in the documentation tab of this web page. 

  • High-purity DI water, slurry, and aggressive chemical monitoring
  • Filtration condition monitoring
  • General pressure monitoring

 

Product tags